MET Calibrations

Overview

Teaching: 20 min
Exercises: 10 min
Questions
  • Why do we need to calibrate MET? How is the performance measured?

  • What are the different ways of calibrating MET at CMS?

  • What is MET phi modulation? How to correct for it?

  • How is the uncertainty on MET estimated?

Objectives
  • Learn about the MET calibration procedure and techniques used at CMS.

  • Learn about measuring MET performance.

  • Understand MET phi modulation and how to account for it.

  • Learn about MET uncertainty sources and to get the MET uncertainty in MiniAOD analyses.

After following the instructions in the setup, make sure you have the CMS environment:

cd $CMSSW_BASE/src/METDAS
cmsenv

MET Corrections

\[\vec{p}_{T}^{~miss,~raw} = - \sum_{i \in all} \vec{p}_{T, i}\]

The MET objects described earlier (PF-MET and PUPPI-MET) are referred to as raw MET, and they are systematically different from the true MET, which corresponds to the transverse momentum carried by invisible particles. This difference arises from factors such as the non-compensating nature of the calorimeters, calorimeter thresholds, and detector misalignment, among others. To improve the MET estimate and make it closer to the true MET, corrections can be applied.

Type-1 Correction

The Type-I correction is the most commonly used MET correction in CMS. It propagates the jet energy corrections (JEC) to MET. Specifically, the Type-I correction replaces the vector sum of the transverse momenta of particles clustered as jets with the vector sum of the transverse momenta of the jets, which have been corrected with JEC.

Particles can be classified into two disjoint sets: those that are clustered as jets and those that remain unclustered.

\[\vec{p}_{T}^{~miss,~raw} = - \sum_{i \in jets} \vec{p}_{T, i} - \sum_{i \in uncl} \vec{p}_{T, i}\]

The first vector sum corresponds to the total pT of all jets:

\[\sum_{i \in jets} \vec{p}_{T, i} = \sum_{i}^{nJets} \vec{p}_{T, jet}^{~uncorr}\]

The superscript “uncorr” indicates that the jet energy correction (JEC) has not yet been applied to these jets.

The Type-I correction replaces the raw jet pT with the corrected jet pT. The Type-I correction can be expressed as the difference between two vector sums:

\[C_{T}^{~Type-1} = \sum_{i}^{nJets} \vec{p}_{T, jet}^{~uncorr} - \sum_{i}^{nJets} \vec{p}_{T, jet}^{~corr}\]

or equivalently:

\[C_{T}^{~Type-1} = \sum_{i \in jets} \vec{p}_{T, i} - \sum_{i}^{nJets} \vec{p}_{T, jet}^{~corr}\]

This vector term can be added to the raw MET to obtain the Type-1 corrected MET:

\[\vec{p}_{T}^{~miss,~Type-1} = \vec{p}_{T}^{~miss,~raw} + C_{T}^{~Type-1}\]

Thus, the Type-I corrected MET is:

\[\vec{p}_{T}^{~miss,~Type-1} = \vec{p}_{T}^{~miss,~raw} - \sum_{i}^{nJets} (\vec{p}_{T, jet}^{~corr} - \vec{p}_{T, jet}^{~uncorr})\]

or equivalently:

\[\vec{p}_{T}^{~miss,~Type-1} = - \sum_{i}^{nJets} \vec{p}_{T, jet}^{~corr} - \sum_{i \in uncl} \vec{p}_{T, i}\]
We will revisit this in MET performance, but this figure shows a comarison between the MET scale for raw PF MET vs Type-1 PF MET.

Type-1 Smear MET (For MC only)

In MC simulations, jets are smeared to achieve better agreement with data. This smearing of MC jets can additionally be propagated to MET, resulting in Type-1 smear MET.

Remember

PF MET is the recommended MET algorithm in Run 2, and PUPPI MET is recommended for Run 3 analyses. Type-I corrected MET is the default MET calibration required in all analyses.

XY corrections

The XY correction reduces the MET $\phi$ modulation. This correction also helps mitigate pile-up effects.

The distribution of true MET is independent of $\phi$ due to the rotational symmetry of collisions around the beam axis. However, we observe that the reconstructed MET does depend on $\phi$. The MET $\phi$ distribution follows roughly a sinusoidal curve with a period of $2\pi$.

The possible causes of this modulation include:

The amplitude of the modulation increases roughly linearly with the number of pile-up interactions.

MET Uncertainty

For analyses sensitive to missing transverse energy — those involving large MET contributions from neutrinos or other signatures — it is necessary to break MET into its individual components. Since MET is calculated as the vector sum of contributions from jets, electrons, muons, taus, photons, and “unclustered energy” (energy not associated with reconstructed objects), the resolution and scale of each component must be propagated to MET. These uncertainties are then treated as separate nuisance parameters each arising from a different physics object.

The physics objects that contribute the most are:

The scale and resolution of each component must be systematically varied within their respective uncertainties. These variations are then propagated to the MET calculation to calculate their impact on the analysis.

Exercise 2.1

In this section, we will focus on accessing the MET object(s) in miniAOD, including:

Firstly, we will access different MET flavors: the raw PFMET, the Type-1 PFMET (the default MET flavor in CMS), and the Type-1 smeared PFMET.
In Type-1 MET, corrections from the jet energy scale are propagated to MET, whereas in Type-1 smeared MET, corrections from both the jet energy scale and the jet energy resolution are applied.

MET relies on accurate momentum/energy measurements of reconstructed physics objects, including muons, electrons, photons, hadronically decaying taus, jets, and unclustered energy (UE). The latter refers to contributions from PF candidates not associated with any of the previously mentioned physics objects.

Since uncertainties in MET measurements strongly depend on the event topology, uncertainties in the momenta of all reconstructed objects are propagated to MET. This is done by varying the momentum estimate of each object within its uncertainty and recomputing MET.
In this exercise, we will consider three sources of uncertainty:

  1. Jet energy scale
  2. Jet energy resolution
  3. Unclustered energy

We will use the same file as in Exercise 1.1.

Execute the following commands inside the CMSSW environment created during setup:

cd $CMSSW_BASE/src/METDAS
cmsRun CMSDAS_MET_Analysis/test/run_CMSDAS_MET_Exercise2_cfg.py

This script will:

The analyzer being run using is command is CMSDAS_MET_Analysis/plugins/CMSDAS_MET_AnalysisExercise2.cc. The printout looks like the following:

Begin processing the 1st record. Run 1, Event 138728702, LumiSection 513811 on stream 0 at 05-Jan-2025 14:40:03.942 CST
 MET : 
  pt [GeV] = 4.42979
  phi [rad] = 2.92774
 MET uncertainties : 
  JES up/down [GeV] = 2.22909/6.63454
  JER up/down [GeV] = 4.34603/4.51426
  Unc up/down [GeV] = 9.2058/6.06604
 MET corrections : 
  Raw PFMET pt [GeV] = 10.7137
  PFMET-type1 pt [GeV] = 4.42979
  Smeared PFMET-type1 pt [GeV] = 4.40847
  .......
  .......

Question 2.1

Compare the distributions of the above quantities and get a feeling about their effect. Wheer are these distrucutions being stored?

Solution 2.1

The various MET histograms (raw, Type-1, JES Up, JER down etc.) are being stored at ./outputs/cmsdas_met_exercise2.root

Exercise 2.2

Now we make the following modifications to the configuration script CMSDAS_MET_Analysis/test/run_CMSDAS_MET_Exercise2_cfg.py:

After these modifications, please re-run the configuration with the following command:

cmsRun CMSDAS_MET_Analysis/test/run_CMSDAS_MET_Exercise2_cfg.py

Once the process completes (it will take a few seconds), it will produce a ROOT file. We will then compare the 1D distribution of different MET flavors in a Z+jets sample (which has no genuine MET). To generate the plot, run the following commands:

cd $CMSSW_BASE/src/METDAS/scripts
root -l -q 'cmsdasmetplotsexercise2.C("step2a")'

Question 2.2

What do you observe looking at the different MET calibration algorithms?

Solution 2.2

Exercise 2.3

Next, we will focus on Type-1 PF MET and study the impact of various uncertainties, including Unclustered, JES, and JER. To generate the corresponding plot, use the following command:

cd $CMSSW_BASE/src/METDAS/scripts
root -l -q 'cmsdasmetplotsexercise2.C("step2b")'

Question 2.3

What do you observe looking at the different sources of MET uncertainty?

Solution 2.3

Key Points

  • Inaccurate MET estimation can result from sources such as non-linearity in the calorimeter’s response to hadrons, minimum energy thresholds in the calorimeters, and pT thresholds or inefficiencies in track reconstruction. These issues are mitigated through calibration procedures discussed in this exercise.

  • Type-1 MET is the default MET calibration recommended by CMS.

  • Type-1 smear MET enhances data-MC agreement, and JME POG advises analysts to assess its impact in their studies.

  • MET is influenced by uncertainties from all contributing objects, including jets, leptons, photons, and unclustered energy. Systematic variations in the scale and resolution of each component must be propagated to the MET calculation to evaluate their impact on the analysis.